Product Details:
Operating Temperature | 0 - 60 DegreeC |
Accuracy | +-0.5 % +-(1mm/sec) of Actual Flow Rate between 100 % to 10 % of calibrated ran |
Display Type | 16 characters x 2 rows LCD Display for instantaneous Flow rate, Totaliser, Engg. units |
Brand | manas microsystems |
Operating Pressure | Up to DN 80 - PN 40 |
Line Size | DN 10 |
Velocity range | Max 10 m/s |
Flanges | Carbon Steel |
Ingress Protection | IP-68 |
Power Supply to field coils | Pulsed DC |
Pipe Material | SS 304 [non-magnetic ] |
Principle Of Operation
The SROAT 1002 series electromagnetic flow meters work on Faraday's law of electromagnetic induction. It, in brief, states; when a conductor moves within a magnetic field, voltage is induced in it which is proportional to the velocity of conductor.
In this case the conductor is flowing media.
The equation is as below :
E = B.V.D
Where
E = Induced voltage (proportional to velocity)
B = Magneticflux density
V = Mean velocity of the media
D = Diameter of flow-sensor (distance between the sensing electrodes)
For a given size of flow tube & compatible amplifier the flux density 'B' is constant, the distance between the electrodes is constant. Hence, the induced voltage is proportional to the flowing media. Thus the meter can be calibrated in terms of volumetric flow rate by knowing the cross-sectional area of the tube.
Principal Advantages
- Robust, rugged, welded steel/stainless steel construction withstanding to IP68.
- Very much suitable for submerged or buried application.
- No Pressure Drop across the sensor, being full bore construction.
- Measurement independent of un-dissolved solids.
- Long lasting Ebonite rubber lining gives long life of sensor,
- End connection flanges as per customer's Requirements.
Applications
The flow meter can be used to measure various types of fluids which can be found across various industrial processes. The accurate readings of meter keeps the operator always alert about flow rates of Medias of process.
Some of the application areas of meter:
- Effluent treatment plants
- Sewage treatment plant
- Water supply schemes
- Steel industry
- Sugar industry and distillery
- Pulp and paper
- Chemical and pharmaceutical
- Food and drug
Other Details:
- Operating Pressure: From DN 100 to DN 200 - PN 16, From DN 250 to DN 350 - PN 10
- Line Size: DN 10 to DN 350
- Flanges: SS 316 / SS 316 L / SS 304.